Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Outcomes of a 1-Year Prospective Single-Arm Cohort Study Using a Novel Macro-Hybrid Implant Design in Extraction Sockets: Part 1
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 41 , Issue 4
July/August 2021

Pages 499–508


Outcomes of a 1-Year Prospective Single-Arm Cohort Study Using a Novel Macro-Hybrid Implant Design in Extraction Sockets: Part 1

Stephen J. Chu, DMD, MSD, CDT/Hanae Saito, DDS, MS/Barry P. Levin, DMD/Harold Baumgarten, DMD/Nicholas Egbert, DDS, MDS/Michael J. Wills, DDS, MD/Robert A. del Castillo, DMD/Dennis P. Tarnow, DDS/Myron Nevins, DDS


PMID: 34328467
DOI: 10.11607/prd.5709

A novel macro-hybrid implant design was introduced to afford high apical primary stability and more coronal space to preserve the circumferential extraction socket architecture. This study presents 1-year data from a prospective single-arm cohort study. The data was distilled based on the following criteria: (1) single-tooth immediate tooth replacement therapy (ITRT) in the maxillary anterior and premolar regions in intact (Type 1) extraction sockets that were (2) treated with the dual-zone grafting technique. The clinical and radiographic outcomes of 48 ITRT implants were evaluated. The mean ± SD labial plate dimension changes were 0.33 ± 0.41 mm at the implant abutment interface (L1) and 0.34 ± 0.40 mm at 5.0 mm below (L2). The mean labial plate dimension (thickness) at the 1-year recall was 2.27 ± 0.88 mm (L1) and 1.95 ± 0.95 mm (L2). At ITRT, the ridge contour at the free gingival margin and 3.0 mm below it were 7.54 ± 0.93 mm and 9.44 ± 2.36 mm, respectively; after final restoration delivery, the corresponding values were 7.45 ± 0.95 mm and 10.23 ± 2.30 mm, respectively. The peri-implant soft tissue thickness (PISTT) at the time of implant-level impression-making was 3.29 ± 0.73 mm, with an average Pink Esthetic Score of 12.79. A macro-hybrid implant design showed high levels of primary stability (~60 Ncm), stable ridge contour at 1 year, a labial plate dimension between 1.5 and 2.0 mm, and PISTT > 3.0 mm, which may be a critical factor in providing stable, long-term esthetic outcomes.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help